Heart has built-in repair mechanism

Researchers have for the first time succeeded in transforming a new type of stem-like cell in the adult heart, into heart muscle in mice.

The study, led by UCL scientists proves the heart has dormant repair cells in its outer layer that may be re-activated. The research suggests that in the future hearts damaged by a heart attack could be encouraged to repair themselves.

The damage caused by a heart attack is currently permanent. It can lead to heart failure, which is debilitating, has a poor prognosis, and affects over 750,000 people in the UK.

British Heart Foundation-funded scientists working at UCL targeted stem-like cells called progenitor cells in the epicardium, the outer layer of the heart. In the embryo, these epicardium-derived progenitor cells (EPDCs) are able to transform into a number of specialist cells including heart muscle. Scientists thought this ability was lost in adults but researchers have managed to reactivate this potential.

EPDC heart cells

They restored the EPDCs’ embryonic potential by treating the healthy hearts of adult mice with a peptide molecule called thymosin β4 (Tβ4). This appeared to ’prime’ the heart for repair. When damage to the heart occurred, a booster dose of Tβ4 was given, and this sparked the EPDCs to transform into new heart muscle and integrate with existing healthy muscle. Crucially, muscle is not formed if the EPDCs have not been pre-treated with Tβ4.

Explaining how this work might eventually translate into clinical practice, Professor Paul Riley (UCL Institute of Child Health), who led the research, said: “I could envisage a patient known to be at risk of a heart attack – either because of family history or warning signs spotted by their GP – taking an oral tablet, along the lines of a statin, which would prime their heart so that if they had a heart attack, the damage could be repaired.”

However, treatments based on this method are several years away. Tβ4 enabled only a limited number of heart muscle cells to be generated. With BHF funding, the researchers now plan to carry out further research into the molecule. They hope to make it more effective or come up with alternative ways to activate the embryonic potential of EPDCs and eventually translate what they have found in mice into humans. This will also be helped by gaining better knowledge of the mechanism by which Tβ4 works.

Professor Riley added: “This is an important piece of work and something we’ve been working toward for some time. Our earlier research proved blood vessels could be regenerated in adult hearts but there were major doubts about whether the same might be true for heart muscle. This work has demonstrated a possible method for repairing hearts damaged by a heart attack and could have a major impact on future therapies to treat heart failure.”

Professor Jeremy Pearson, Associate Medical Director at the BHF, said:

“To repair a damaged heart is one of the holy grails of heart research. This groundbreaking study shows that adult hearts contain cells that, given the right stimulus, can mobilise and turn into new heart cells that might repair a damaged heart. The team have identified the crucial molecular signals needed to make this happen.

“These results strengthen the evidence that in the future there may be a drug, or cocktail of drugs, that could be given to people whose hearts have been damaged by a heart attack, to prevent the onset of heart failure. This is why the BHF has launched its Mending Broken Hearts appeal to raise money for research to turn this vision into reality for heart patients as quickly as possible.”

A fiducial marker based technique for alignment of simultaneously acquired PET and MRI images

Combined MRI and PET systems are currently being developed by a number of research groups and also commercially. Most systems have been designed to permit the simultaneous acquisition of MRI and PET data. The approach taken by many groups, is to build an MRI compatible PET insert, that works inside a standard MRI scanner. Unlike other multi-modality imaging systems such as PET/CT, the physical location of the PET scanner within the MRI scanner may vary each time the PET scanner is removed and replaced in the MRI scanner. In order to produce fully aligned PET and MRI images over the same region of the subject, the PET scanner location within the MRI field of view (FOV) is required, as well as the transformation between the PET and the MRI images. We have developed such a technique for our single slice pre-clinical MR-compatible PET system that uses long optical fibres to distance the PET PMTs from the high field at the centre of the MRI scanner. The method uses MRI visible markers attached to the PET scanner at a known position with respect to the PET FOV. In our configuration the markers must be positioned close to MRI compatible PET gamma shields which are used to improve the signal to noise ratio of the PET images by reducing the number of events recorded from activity outside the FOV. These shields are made from BGO and PbO, which have similar magnetic properties to LSO. The main magnetic field of the MRI scanner becomes distorted near to the shields, although they impose little distortion over the useful FOV of the PET system. We have assessed the accuracy with which the MRI visible markers can be used to select the location of the PET imaging slice and to align the PET and MRI images in-plane, using simultaneously acquired data of various phantoms. In order to carry out the in-plane registration, two separate MRI images had to be acquired in which the direction of the MRI frequency-encoding gradient was flipped between the two acquisitions to estimate the in-pl- - ane shift in marker location caused by field inhomogeneities imposed by the PET shielding materials. The slice location accuracy and the in-plane registration appear to be accurate to approximately 0.5 mm. We have successfully applied the method to produce simultaneously acquired, registered 18F-PET and MRI images of the mouse neck. A similar method is likely to be required for many future pre-clinical simultaneous PET and MRI studies as it will be essential for situations in which there is little similarity between the PET and MRI images.

STATIC MAGNETIC FEILD OF MRI

There are three important or main components in an MRI scanner static magnetic field, radio frequency coils and gradient coils which majorly contribute towards creating of images, yet there are other components also...
Static magnetic field
it is an absolute necessity for MRI, providing the magnetic in magnetic resonance imaging.MRI scanner use strong magnetic field to align certain nuclei within the human body (commonly Hydrogen) to allow mapping of tissue properties. The magnetic field strength is in fact proportional to current strength ,so that by adjusting the current strength in a wire one could precisely control field intensity .these findings led to the development of electromagnets ,which generate their fields by passing current through tight coils of wire .Nearly all scanners today create static magnetic field through electromagnetism. There are in general two criteria for a suitable magnetic field in MRI ,the first is uniformity (homogeneity) and second is strength. Uniformity is necessary in what we want to create Images of the body that do not depend on which MRI scanner we are using or how the body is positioned in the field .If magnetic field were Inhomogeneous,the signal measured from a given part of the body would depend upon where it is located in the magnetic field

A simple design for generating a homogeneous magnetic field is the HELMHOLTZ PAIR

This is a pair of circular loops that carry identical current and are separated by a distance equal to the radius of the loops, an even more uniform field can be generated by a Solenoid, and the internal field near its center is highly homogeneous

Field Strength in contrast to uniformity requires force rather than finesse, to generate this field, we require enormous electric power and thus enormous expense.MRI scanners use Super conducting electromagnets whose wires are cooled by cryogens (liquid helium) to reduce their temperature to near absolute zero. Coil windings are typically made of metal alloys such as niobium-titanium, which when immersed in liquid helium reach temperatures of less than 12K (-261 deg).At this extremely low temperature ,the resistance in the wire disappears thereby enabling a strong and lasting electric current to be generated with no power requirements and minimal cost