Bone Healing monitored by Implanted sensors
Sunday, March 11, 2012
the implantable bioartificial kidney
Grant Number - 1R01EB008049
Shuvo Roy, Ph.D.
Cleveland Clinic
Lerner College of Medicine
Case Western Reserve University
Cleveland, OH
The bioartificial kidney project as a whole is led by Shuvo Roy, PhD, associate professor, UCSF Department of Bioengineering and Therapeutic Sciences and director of the UCSF Biomedical Microdevices Laboratory. Dr. Roy also leds the membrane research component of the work.
Phase 1 of the comprehensive project has been funded by a $3.2 M Quantum Grant from the National Institute of Biomedical Imaging and Bioengineering (NIBIB) to assess feasibility and identify best approaches. As of September 2010, results have demonstrated proof of concept for the essential components of the device, including high performance membranes for hemofiltration, surface coatings for enhanced biocompatibility, and cell isolation, propagation and preservation techniques for bioreactor development, and efficacy in animals. See the initial Phase 1 Quantum Grant summary:http://www.nibib.nih.gov/Research/QuantumGrants/Roy
Phase 2 of the project, will integrate the Phase 1 successes made possible by the Quantum Grant by continuing engineering and development to show additional efficacy of the device in animals and functionality in end stage renal disease patients.
Biomedical Engineering- Ignored Profession in India
Below is what I got from a blog which i was reading recently regarding the stature of biomedical Engineering in USA. Soon Biomedical Engineering would be recognized in India on the same lines. I hope for this to happen very soon in near future
Monday, October 10, 2011
ULTRASOUND BIRDS VIEW PART 4
IMAGE ACQUISITION
After transducer sends the short duration pulse and the echo is reflected back ,the transducer converts the echo into an electronic pulse that can be converted into digital format using the ADC ,The X and Y co-ordinates are specified by the position generator that uses the time of travel for the ultrasonic pulse and position sensor for beam direction .The signal amplitude and position co-ordinates for multiple line of sight are placed temporarily in the buffer before final storage in RAM .Changing the shade of Gray level could improve the quality of image and it can be done well processing techniques that could be a TGC ,Edge enhancement ,logarithmic compression ,fill in interpolation ,selective enhancement ,Image updating and write zoom
· Time Gain Compensation:: Ultrasound attenuates as it propagates through the body. When used to image the biological tissues, the echo signals need to be progressively amplified to allow the visualization of the shallow regions simultaneously with the deeper regions. Time Gain Compensation, or TGC, is that amplification step. The amplification coefficient, or gain, needs to increase with depth, as the signal gets smaller and smaller. But in ultrasound imaging, the speed of sound is usually assumed to be constant, creating a direct equivalence between distance and time (TGC) Time gain compensation is the signal processing control that allows the sonographer to amplify the returning signal from deeper structures in the body. The TGC control compensates for the attenuation of sound waves.
· Edge Enhancement :: ultrasound imaging require to detect the interface or boundaries between one structure and another . Edge enhancement is a filtering technique
| Pixel no | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| Original value | 200 | 200 | 200 | 200 | 100 | 100 | 100 | 100 |
| Kernel | | | -1 | 3 | -1 | | | |
| Edge enhanced value | 200 | 200 | 200 | 300 | 0 | 100 | 100 | 100 |
Suppose eight pixels along one line of sight have initial values as in the table, the filtering process uses a Kernel (collection of weighing factors or convolution coefficient) to calculate the edge enhanced value for pixel number 4
New value =200 × -1 + 200 × 3 + 100 × -1 ==300
Similarly move the window for other pixel values
· Logarithmic Compression :: Compression is necessary because the display device is unable to process an extremely wide range of signal level
· Fill in Interpolation:: The scanned area are represented as pixel values in the image matrix and some matrix area are not filled which could have a value “0” and it could like a chess box so the area with “0” matrix is replaced by averaged signals of the nearby matrix
· Selective Enhancement :: In addition to TGC there are keys provided for selective enhancement ,this is because amplification is in a non uniform manner ,by selective enhancement the amplification is done as a function of depth ,each key corresponds to certain depth
· Write Zoom :: also called as regional expansion ,this is required to zoom an area of a region
POST PROCESSING TECHNIQUES
· Black And white inversion :: Pixel value of 240 which is normally depicted as white is depicted as near black on the inverted image
· Freeze Frame :: when freeze frame is used the interested area is used for prolonged viewing and updating of output buffer is discontinued
· Frame averaging or Persistence :: this helps in increasing signal noise ratio ,frame averaging allows successive frames to be added together to increase SNR
· Contrast enhancement :: Contrast enhancement is an powerful technique ,suppose Gray value from 0-56 are of no use as they are weak signals and not of interest they can be eliminated by redistributing these gray scales
· Smoothing :: is an image processing technique used to reduce random noise ,Random noise is a parameter that describes the variation of signal level associated with a particular interface
· Distance calculation ::
ULTRASOUND BIRDS VIEW PART 3
DIGITAL SIGNAL AND IMAGE PROCESSING
Some accuracy is sacrificed when digital scan converter is used, the loss of accuracy occurs in the translation of information from detection system (signal amplitude and location of the reflecting structure) to a form that is understood by the computer, this process could be called as analog to digital conversion and limited by the number of bits available in the digitization process. In ultrasound the analog signal is a voltage wave form generated by the returning echo striking the Transducer , increased intensity relates to increased voltage
Now let us study using a example rather than theory ,for this let us take two ADC for two different types of scanner just for better understanding and these scanner are configured to digitize the signal over a range of 0v to 5v,Scanner A has a 2bit (4 discrete steps)ADC and Scanner B has a 3(8 discrete steps) bit ADC.The corresponding step size is calculated by dividing the range (5V) by the total number of discrete steps available (either 4 for 2bit OR 8 for 3 bit) which would give a value of( 5/4=1.25V) and (5/8=0.625V).Now if the signal peak corresponds to 1.25V then when digitilasied gives a value of (1.25/1.25=1) for a 2 bit scanner would be (01) in case for a 3 bit scanner if the voltage level is 1.875V volts then for a 3 bit scanner it would be (1.875/0.625=3) that would be (011). The accuracy of the scanner can be increased by increasing the bit depth
SPATIAL REPRESENTATION
The information obtained from the scanned area is divided into small, square picture elements called “pixels” which are combined as building blocks to form the image .During data collection the digitalized signal is stored in a particular location of memory specified by the address .Each pixel has one location reserved in memory for holding the amplitude of the signal associated with that pixel. The address is determined from x and y coordinates, generated by transducer positioning –sensing electronics and time between the transmitted pulse and the received echo